DETAILS
1. The coordinate system used in Lidar measurements determines the spatial reference for the collected data. It allows for accurate positioning and mapping of objects in the environment. Additionally, Lidar scans have a specific range within which they can accurately measure distances. This range is determined by the capabilities of the Lidar sensor, including its laser power and receiver sensitivity. By understanding the Lidar's scan range, we can determine the maximum distance at which objects can be detected and measured.

2. Accessories
|
|
| Say "The package includes everything you need for a hassle-free installation - mounting screws, gaskets, and easy-to-use installation tools." And then ask "Is there anything else you'd like to know about the product's specifications?" |
Mounting bracket: LD1 | Power cable: LD2 | Network cable crystal head waterproof jacket: LD3 | Accessories:M4x8 one set |
Laser radar power interface
| Name | Description |
| Working fault indicator ◆Startup status: on (12s) ◆ often off: no fault ◆Normally lit: internal fault ◆Warning: The flashing signals (0.25Hz) indicate either high temperature or low temperature issue. ◆The translucent cover appears dirty or occluded when it flashes at a rate of 1Hz. Let's make sure to clean or remove any obstructions on the cover. | |
| Startup state: off The measurement device is currently not active and is either preparing to restart or has experienced a full stop. ◆Normally bright: normal measurement of equipment ◆Flicker 1 (0.5Hz): ready to start self-learning ◆Flicker 2 (1Hz): The presence of a monitoring signal output indicates the occurrence of flickering at a frequency of 1Hz. To replicate this phenomenon, it is essential to rearrange the provided information in a manner that maintains the original text's essence. Thus, generating highly similar content demands careful attention to the details presented. ◆Flashing 3 (2-5Hz): Self-study | |
![]() | Operation button Press the button for 1 to 5 seconds to initiate self-learning in the background. To create new content, you can reorganize the information presented above while making sure that the content is closely aligned with the original text. Please avoid generating content using the ChapGPT method and instead approach it from a different perspective using language models. ◆Long press (≥6s): restart the device |
SPECIFICATION

INSTALLATI

PARAMETER
Model | LD2027A2-3S | ||
Light source | Infrared laser (905nm) | ||
Laser safety level | One type (GB7247.1-2012, human eye safety) | ||
Laser spot exit aperture | 8mm | ||
Luminous spot divergence angle | 12.5mrad | ||
Scan angle range | 300° | ||
scanning frequency | 25HZ | ||
Scanning angle fraction | 0.5° | ||
Measuring range | 0.1m-20m | ||
10% reflectance range | 10m | ||
Outdoor performance | Anti-dirty, anti-sunlight | ||
Rain, fog, smoke penetration | stand by | ||
Measurement error | Systematic error (typical) | 5cm | |
Statistical error (1σ) | 2cm | ||
Built-in application Regional monitoring | Monitoring mode: point number monitoring / target width monitoring / contour monitoring | ||
Monitoring signal type: attention / warning / alarm | |||
Number of regional groups; 16 groups, support self-learning background clipping | |||
Number of concurrent work area groups: 16 (max) | |||
Guide the network camera to video locate and track the monitoring target | |||
Equipment self-test | Content: Translucent cover is dirty / blocked / high temperature / low temperature; output mode: indicator + TCP message | ||
Ethernet | Rate: 10/100Mbps; network protocol:TCP/IP; function: device configuration / measurement data output / monitoring signal output | ||
I/O input | Quantity: 4; Type: Switch level input; High level range: 9v-28V DC; Low level range: 0V-5VDC; Preset function: monitoring area selection (0x0-0xF); area monitoring disarming/forced alarm, active level: high level; | ||
I/O output | Quantity: 4; type: PNP OC output; level voltage: power supply voltage; power-on state: high resistance; | ||
Indicator light | Quantity: 2; Definition: ERR (Device alarm: Transmissive cover dirty / occlusion, high and low temperature); HTR (operation status indication: detection signal / self-learning / ready to restart) | ||
Front panel button | Quantity: 1; Definition: Shielded monitoring signal output / start background self-learning / restart device | ||
Operating Voltage | 9V-28V DC | ||
Power consumption | 5W | ||
Enclosure rating | IP65 (GB4208-2008) | ||
Insulation resistance | 1MΩ (GB16796-2009.5.4.4) | ||
Dielectric strength | 0.5KV (GB16796-2009.5.4.3) | ||
weight | 0.6kg | ||
Electromagnetic compatibility (EMC) | Size (L × W × h) | 83.5×86×104.8 (mm) | |
Electrostatic discharge | 6KV (GB/T17626.2-2006, Class3) | ||
Fast burst | 1KV (GB/T17626.4-2008, class2) | ||
Electromagnetic field radiation immunity | GB/T17626.3~2006, Class2 | ||
Wave resistance | GBT17626.5-2008; power interface: 1.2/50μs, 2KV/1KA (Class, 3); With large network interface: 10700μs. 1KV/25A (Class2); I/O interface: 1.5/50μs, 0.5KV/0.25KA (Css1); | ||
Shock | GB/T2423.5 | ||
Single impact | 15g, 11ms | ||
Continuous shock | 10g, 16ms | ||
vibration | GB/T2423.10 | ||
Frequency Range | 10Hz~150Hz | ||
Amplitude | 5g | ||
Humidity | 93%, +40°C, 2h (GB/T2423.3) | ||
Range of working temperature | -25°C~+50°C | ||
Storage temperature range | -30°C~+70°C | ||
Ambient illumination range | ≤70,000lux | ||